FRAME BUILDER - VOL7 NO3 / 37 of the cylinder. Fortunately, the horizontal component of the cylinder force F can be calculated if the vertical location of the cylinder to frame attachment is known. This is done by summing moments about the upper hinge. It can also be observed that the door weight W is equal to the sum of W1 and W2. It is common practice to apply the full door weight to the jamb columns at the upper hinge elevation despite the fact that a portion of the door weight is supported by the cylinder and the door frame may transfer some load to the foundation if present. This practice eliminates the need to calculate W1. The need for information about cylinder orientation is thus avoided. The above ignores the contribution of the vertical doorframe in distributing the hydraulic ram force. The argument for making this assumption here is the same as that made in the wind suction case. The stiffness of the jamb column is typically several times that of the doorframe. Hence the jamb column will attract the bulk of the force from the resisting couple at a location near the cylinder attachment. Mono-fold doors can impose significant dynamic effects. These have been ignored in the loading procedure outlined above. It is believed that the redundancy resulting from ignoring the steel door frame and the energy absorptive characteristics of wood construction allow dynamic effects to be safely ignored. Even so, use of soft start/stop technology in the hydraulic circuit as a means of minimizing dynamic effects is highly recommended. Building Design The building, jamb columns, bracing and connections must be designed to safely absorb the forces produced by mono and bi-fold doors when they are included in the structure. Building design is beyond the scope of this article. Suffice to say, the forces generated by large doors can be significant. A competent post-frame design professional should be engaged to ensure a successful project. Conclusion Mono and bi-fold doors load the buildings into which they are installed in unique ways. The large sizes of these doors mean the loads can be very large, easily controlling the design of door framing elements. The above discussion provides a rational framework for determining the forces imposed by mono and bi-fold doors. Sizing building components and connections based on the resulting forces have resulted in several buildings that have performed well. Paul Boor Vice President Of Engineering & Product Development at Lester Building Systems, LLC This article was reviewed and approved to be reprinted by the NFBA Editorial Committee, which consists of at least 10 members from engineering and academic organizations throughout the United States who are each knowledgeable about Post-Frame construction. YOUR TOOLKIT FOR BUILDING EXCELLENCE Photo Courtesy of Wick Buildings
View this content as a flipbook by clicking here.